Compact Converters (CC)
OVERVIEW
Description
Virginia Diodes offers compact converters (CCs) for frequency up and down-conversion. These converters are easy to use and well suited for high performance up and down conversion of wide band modulated millimeter-wave signals. VDI CCs offer full waveguide band coverage and are available from WR28 (22.5-40 GHz) to WR10 (75-110 GHz) with additional CCs under development. Compact converters can typically be delivered within 8 weeks ARO or less. Contact VDI for more information.
Due to the double sideband nature of the CCUs, two sidebands (upper and lower sidebands) are generated during the upconversion process. A filter may be preferred for certain applications to eliminate one sideband. Click here for more information about our band pass filters.
VDI also offers waveguide amplifiers to boost the transmitted signal power out of the up-converter. Click here for more information about our amplifiers.
Compact Converter Configurations
Compact Up-Converter (CCU)
Compact Down-Converter (CCD)
PRODUCTS
Product Specifications (WR28 to WR12)
Product Specifications for Compact Up-Converters (CCU) |
||||
WR28CCU | WR19CCU | WR15CCU | WR12CCU | |
LO Input Frequency (GHz) |
22.5-40 | 20-30 | 25-37.5 | 30-45 |
PLO, LO Input Power (dBm, typical / damage)* | 0 / 10 | 0-3 / 6 | 0-6 / 9 | 0-6 / 9 |
IF Input Frequency (GHz) | 0.01-8.5 | 0.01-6 | 0.01-9 | 0.01-12 |
PIF, IF Input Power (dBm, ~P1dB / ~P0.1dB) | 8 / -5 | -4 / -14 | PLO - 10dB / PLO - 20dB | |
PIF, IF Input Power (dBm, damage) | 10 | 6 | 0 | |
RF Output Frequency (GHz) | 22.5-40 | 40-60 | 50-75 | 60-90 |
RF Output Flange | WR-28 UG-599/U-M | WR-19 UG-599/U-M | WR-15 UG-387/U-M | WR-12 UG-387/U-M |
LO Input Connector | 2.92mm(f) | 2.92mm(f) | 2.92mm(f) | 2.4mm(f) |
IF Input Connector | 2.92mm(f) | |||
Conversion Loss (typ., dB)†† | 10 | 10 | 10 | 10 |
Operating Temperature (Typical / Recommended) |
25°C / 20-30°C | |||
Typical Dimensions (in., without footplate) | 3.75 x 3.00 x 1.50 |
Product Specifications for Compact Down-Converters (CCD) |
||||
WR28CCD | WR19CCD | WR15CCD | WR12CCD | |
LO Input Frequency (GHz) |
22.5-40 | 20-30 | 25-37.5 | 30-45 |
PLO, LO Input Power (dBm, typical / damage) | 0 / 10 | 0-3 / 6 | 0-6 / 9 | 0-6 / 9 |
IF Output Frequency (GHz) | 0.0001-8.5 | 0.0001-6 | 0.0001-9 | 0.0001-12 |
PRF, RF Input Power (dBm, ~P1dB / ~P0.1dB) | 8 / -5 | -4 / -14 | PLO - 10dB / PLO - 20dB | |
PRF, RF Input Power (dBm, damage) | 10 | 6 | 0 | |
IF Amplifier Gain (dB)† | ~12 | |||
RF Input Frequency (GHz) | 22.5-40 | 40-60 | 50-75 | 60-90 |
RF Input Flange | WR-28 UG-599/U-M | WR-19 UG-599/U-M | WR-15 UG-387/U-M | WR-12 UG-387/U-M |
LO Input Connector | 2.92mm(f) | 2.92mm(f) | 2.92mm(f) | 2.4mm(f) |
IF Output Connector | 2.92mm(f) | |||
Conversion Loss (typ., dB)†† | 10 | 10 | 10 | 10 |
Operating Temperature (Typical / Recommended) |
25°C / 20-30°C | |||
Typical Dimensions (in., without footplate) | 3.75 x 3.00 x 1.50 |
*LO Input Power for optimal conversion loss varies with LO input frequency.
†CCD modules include an IF amplifier with ~12dB gain.
††Conversion Loss is defined as the intrinsic mixer conversion loss without any external amplifiers.
General Notes:
•VDI CCs include a single volt power supply.
•The required LO power for optimal performance varies across the frequency band. Performance specifications assume optimal RF and LO power coupled into the mixer; performance may be reduced near band edges.
•Conversion Loss performance is specified at ~1 GHz IF. Conversion loss increases as a function of IF, at a rate of ~1.5dB/10GHz, up to the specified Maximum IF Frequency. Performance is typical with reduced performance at band edges.
•RF Filters can be used to eliminate one sideband of the CCR RF output. Contact VDI for more information.
•RF amplifiers can be used to increase the CCU RF output power. Contact VDI for more information.
•Where available, an input isolator will smooth the required LO input power vs. frequency.
Product Specifications (WR10 and Higher Frequency)
Product Specifications for Compact Up-Converters (CCU) |
||||
WR10CCU | WR6.5CCU | WR6.5CCU-M12 | WR5.1CCU | |
LO Input Frequency (GHz) |
37.5-55 | 18.3-28.3 | 9.2-14.2 | 23.3-36.7 |
PLO, LO Input Power (dBm, typical / damage) | 6-12 / 15** | 0-6 / 12 | 0-6 / 12 | 0-6 / 12 |
IF Input Frequency (GHz) | 0.01-15 | 0.01-17 | 0.01-17 | 0.01-22 |
PIF, IF Input Power (dBm, ~P1dB / ~P0.1dB) | PLO - 10dB / PLO - 20dB | -1 / -11 | ||
PIF, IF Input Power (dBm, damage) | 0 | 6 | ||
RF Output Frequency (GHz) | 75-110 | 110-170 | 110-170 | 140-220 |
RF Output Flange | WR-10 UG-387/U-M | WR-6.5 UG-387/U-M | WR-6.5 UG-387/U-M | WR-10 UG-387/U-M |
LO Input Connector | 1.85mm(f) | 2.92mm(f) | 2.92mm(f) | 2.92mm(f) |
IF Input Connector | 2.92mm(f) | |||
Conversion Loss (typ., dB)†† | 10 | 10 | 10 | 12 |
Operating Temperature (Typical / Recommended) |
25°C / 20-30°C | |||
Typical Dimensions (in., without footplate) | 3.75 x 3.00 x 1.50 | 5.00 x 3.50 x 1.50 |
Product Specifications for Compact Down-Converters (CCD) |
||||
WR10CCD | WR6.5CCD | WR6.5CCD-M12 | WR5.1CCD | |
LO Input Frequency (GHz) |
37.5-55 | 18.3-28.3 | 9.2-14.2 | 23.3-36.7 |
PLO, LO Input Power (dBm, typical / damage) | 6-12 / 15** | 0-6 / 12 | 0-6 / 12 | 0-6 / 12 |
IF Output Frequency (GHz) | 0.0001-15 | 0.0001-17 | 0.0001-17 | 0.0001-22 |
PRF, RF Input Power (dBm, ~P1dB / ~P0.1dB) | PLO - 10dB / PLO - 20dB | -1 / -11 | ||
PRF, RF Input Power (dBm, damage) | 0 | 6 | ||
IF Amplifier Gain (dB)† | ~12 | |||
RF Input Frequency (GHz) | 75-110 | 110-170 | 110-170 | 140-220 |
RF Input Flange | WR-10 UG-387/U-M | WR-6.5 UG-387/U-M | WR-6.5 UG-387/U-M | WR-5.1 UG-387/U-M |
LO Input Connector | 1.85mm(f) | 2.92mm(f) | 2.92mm(f) | 2.92mm(f) |
IF Output Connector | 2.92mm(f) | |||
Conversion Loss (typ., dB)†† | 10 | 10 | 10 | 12 |
Operating Temperature (Typical / Recommended) |
25°C / 20-30°C | |||
Typical Dimensions (in., without footplate) | 3.75 x 3.00 x 1.50 | 5.00 x 3.50 x 1.50 |
.
**LO Input Power for optimal conversion loss varies with LO input frequency.
†CCD modules include an IF amplifier with ~12dB gain.
††Conversion Loss is defined as the intrinsic mixer conversion loss without any external amplifiers.
General Notes:
•VDI CCs include a single volt power supply.
•The required LO power for optimal performance varies across the frequency band. Performance specifications assume optimal RF and LO power coupled into the mixer; performance may be reduced near band edges.
•Conversion Loss performance is specified at ~1 GHz IF. Conversion loss increases as a function of IF, at a rate of ~1.5dB/10GHz, up to the specified Maximum IF Frequency. Performance is typical with reduced performance at band edges.
•RF Filters can be used to eliminate one sideband of the CCR RF output. Contact VDI for more information.
•RF amplifiers can be used to increase the CCU RF output power. Contact VDI for more information.
•Where available, an input isolator will smooth the required LO input power vs. frequency.
Performance Plots
Contact [email protected] for more information.
HIGH POWER (New!)
CCU-B and CCD-B Product Specifications (WR19 to WR10)
CCU-B Specifications |
||||
WR19CCU-B | WR15CCU-B | WR12CCU-B | WR10CCU-B | |
RF Output Frequency (GHz) | 40-60 | 50-75 | 60-90 | 75-110 |
LO Harmonic Factor | 2 | 2 | 2 | 4 |
LO Input Frequency (GHz) | 20-30 | 25-37.5 | 30-45 | 18.75-27.5 |
PLO, LO Input Power (dBm, typical / damage) | 0-6 / 9 | 0-6 / 9 | 0-6 / 9 | 0-6 / 9 |
IF Input Frequency (GHz) | 0.01-9 | 0.01-9 | 0.01-12 | 0.01-15 |
PIF, IF Input Power (dBm, ~P1dB / ~P0.1dB) | +5 / -5 | +5 / -5 | +5 / -5 | +5 / -5 |
PIF, IF Input Power (dBm, damage) | 15 | 15 | 15 | 15 |
RF Output Flange | WR-19 UG-599/U-M | WR-15 UG-387/U-M | WR-12 UG-387/U-M | WR-10 UG-387/U-M |
LO Input Connector | 2.92mm(f) | 2.92mm(f) | 2.4mm(f) | 2.9mm(f) |
IF Input Connector | 2.92mm(f) | |||
Conversion Loss (typ., dB)† | 10 | 10 | 10 | 10 |
Operating Temperature (Typical) | 20-30°C | |||
Typical Dimensions (in., without footplate) | 5.00 x 3.50 x 1.50 |
†Conversion Loss is defined as the intrinsic mixer conversion loss without any external amplifiers.
CCD-B Specifications |
||||
WR19CCD-B | WR15CCD-B | WR12CCD-B | WR10CCD-B | |
RF Output Frequency (GHz) | 40-60 | 50-75 | 60-90 | 75-110 |
LO Harmonic Factor | 2 | 2 | 2 | 4 |
LO Input Frequency (GHz) | 20-30 | 25-37.5 | 30-45 | 18.75-27.5 |
PLO, LO Input Power (dBm, typical / damage) | 0-6 / 9 | 0-6 / 9 | 0-6 / 9 | 0-6 / 9 |
IF Input Frequency (GHz) | 0.01-9 | 0.01-9 | 0.01-12 | 0.01-15 |
PRF, RF Input Power (dBm, ~P1dB / ~P0.1dB) | +5 / -5 | +5 / -5 | +5 / -5 | +5 / -5 |
PRF, RF Input Power (dBm, damage) | 15 | 15 | 15 | 15 |
IF Amplifier Gain (dB)†† | ~12 | ~12 | ~12 | ~12 |
RF Output Flange | WR-19 UG-599/U-M | WR-15 UG-387/U-M | WR-12 UG-387/U-M | WR-10 UG-387/U-M |
LO Input Connector | 2.92mm(f) | 2.92mm(f) | 2.4mm(f) | 2.9mm(f) |
IF Input Connector | 2.92mm(f) | |||
Conversion Loss (typ., dB)† | 10 | 10 | 10 | 10 |
Operating Temperature (Typical) | 20-30°C | |||
Typical Dimensions (in., without footplate) | 5.00 x 3.50 x 1.50 |
†Conversion Loss is defined as the inttrinsic mixer conversion loss without any external amplifiers.
††CCD-B modules include an IF amplifier with ~12dB gain.
General Notes:
•All CCs include a single volt power supply.
•Conversion Loss performance is specified at ~1 GHz IF. Conversion loss increases as a function of IF, at a rate of ~1.5dB/10GHz, up to the specified Maximum IF Frequency.
Performance is typical with reduced performance at band edges.
•RF Filters can be used to eliminate one sideband of the CCU-B RF output. Contact VDI for more information.
•RF amplifiers can be used to increase the CCU-B RF output power. Contact VDI for more information.